Included for free with your user account is the ability to create four data logs per module that log digital and analog input at 10 to 60 minute intervals. You can set the frequency at which the data is log, view historical graphs, and download the log file.
Log an analog input at a specific interval.
I/O channel settings
Channel Push Update Mode: Push Analog Input Value Periodically
Auto Message Period: greater than zero and less than or equal to the data log frequency
Average the analog inputs collected over a period of time. This is similar to Analog Input Logging except multiple data points received within a specific period will be averaged together and recorded as a single data point.
I/O channel settings
Channel Push Update Mode: Push Analog Input Value Periodically
Auto Message Period: greater than zero and less than or equal to the data log frequency
Log a digital input at a specific interval.
I/O channel settings
Channel Push Update Mode: Push Digital Input State Periodically
Auto Message Period: greater than zero and less than or equal to the data log frequency
Count the number of digital state transitions.
I/O channel settings
Channel Push Update Mode: Push Update on Digital State Change
Log the pulse count from a module channel via the digital input pin.
I/O channel settings
Pulse Count Type: Negative Edge Counting
Pulse Count Type: Positive Edge Counting
Pulse Count Type: Both Negative and Positive Edge Counting
Onboard Rule
Add Rule »
Push Update Rule »
Pulse Count (Push at Interval and Reset Count) »
Select Channel »
Enter a push interval in seconds
To create a log, select the Modules tab and click “Add Log”. You get to choose the log type, module, channel, frequency, analog scale, and digital state options.